Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 12 rekordów  1 - 10następny  skocz do rekordu: Szukanie trwało 0.01 sekund. 
1.
OUTDOOR INSULATORS AND HOUSINGS BREAKDOWNS CAUSED BY POLLUTION / Chrzan, K L ; Znaidi, R [ENY-ARTICLE-2012-310]
A heavy pollution on outdoor insulators causes electrical discharges, flashovers, surface erosion or tracking. [...]
http://zet10.ipee.pwr.wroc.pl/record/397/files/
Rekord szczegółowy - Podobne rekordy
2.
Performance of polymer concrete insulators under light pollution / Chrzan, K L ; Skoczylas, M [I07/2007/I-041] [ENY-ARTICLE-2008-188]
Abstract: This paper deals with polymer concrete, a highly filled composite material as a low cost alternative to porcelain outdoor insulators. [...]
http://zet10.ipee.pwr.wroc.pl/record/239/files/
Rekord szczegółowy - Podobne rekordy
3.
Concentrated Discharges and Dry Bands on Polluted Outdoor Insulators / Chrzan, K L ; Moro, F [I07/2007/I-002] [ENY-ARTICLE-2008-184]
This paper describes concentrated discharges on polluted insulators in the laboratory and in the field. [...]
http://zet10.ipee.pwr.wroc.pl/record/235/files/
Rekord szczegółowy - Podobne rekordy
4.
Application of silicone coatings on porcelain insulators in Poland, a case study / Chrzan, K L [ENY-ARTICLE-2008-219]
Silicone coatings have been used to improve insulating properties of outdoor insulators under polluted conditions for over 30 years. [...]
http://zet10.ipee.pwr.wroc.pl/record/273/files/
Rekord szczegółowy - Podobne rekordy
5.
Termovision diagnostics of metal oxide surge arresters / Chrzan, K L [I07/2007/I-043] [ENY-ARTICLE-2008-187]
The surge arresters diagnostics based on infrared temperature measurement was evaluated. [...]
http://zet10.ipee.pwr.wroc.pl/record/238/files/
Rekord szczegółowy - Podobne rekordy
6.
Effect of silicone rubber insulators' profiles on their ageing performance in rain conditions / Bretuj, W ; Fleszynski, J ; Tyman, A ; Wieczorek, K [ENY-ARTICLE-2009-236]
Numerous studies have been conducted to understand the effect of insulator profiles on ceramic insulators, whereas for polymer insulators this problem has not sufficiently examined. [...]
http://zet10.ipee.pwr.wroc.pl/record/295/files/
Rekord szczegółowy - Podobne rekordy
7.
Pollution flashover of single unit metal oxide arresters / Chrzan, K L ; Koehler, W. [ENY-ARTICLE-2013-342]
Flashover voltage of uniform and non-uniform polluted metal oxide arresters and their porcelain housings without internal parts was measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/429/files/
Rekord szczegółowy - Podobne rekordy
8.
Behaviour of Insulators and Surge Arresters at Glogow Pollution Test Station / Chrzan, K L ; Haddad, A [I07/2005/I-005] [ENY-ARTICLE-2008-222]
The paper reports on the pollution performance of different insulators and surge arresters at Glogow test station from 1981 up to 2004. [...]
http://zet10.ipee.pwr.wroc.pl/record/277/files/
Rekord szczegółowy - Podobne rekordy
9.
Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Rekord szczegółowy - Podobne rekordy
10.
Artificial rain test of outdoor long rod insulators / Chrzan, K L ; Streubel, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-279]
Due to the decrease of industrial contamination emission nearly the whole territory of Poland belongs to the pollution class light. [...]
http://zet10.ipee.pwr.wroc.pl/record/347/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:397 w Google Books
recid:397 w Google Scholar
recid:397 w Google Web
recid:397 w INSPEC