Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 8 rekordów  Szukanie trwało 0.00 sekund. 
1.
PSPICE appliction for modelling of cap and pin insulator strings / Chrzan, K L ; Rebizant, W [ENY-ARTICLE-2012-318]
The use of PSPICE program in HV engineering is shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/405/files/
Rekord szczegółowy - Podobne rekordy
2.
Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Rekord szczegółowy - Podobne rekordy
3.
Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Rekord szczegółowy - Podobne rekordy
4.
Influence of pollution layer thickness on flashover voltage of HV insulators / Wankowicz, J ; Chrzan, K L ; Pohl, Z [ENY-ARTICLE-2012-325]
The pollution characteristics (the relationships of flashover voltage and SDD or maximum current Imax ) for insulators contaminated with uniform or nonuniform coatings with different thickness h are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/412/files/
Rekord szczegółowy - Podobne rekordy
5.
Hygroscopic Properties of Pollutants on HV Insulators / Chrzan, K L ; Pohl, Z ; Kowalak, T [I07/1988/P-337] [ENY-ARTICLE-2008-212]
The mechanism of moisture absorption by an insulator surface contaminated with different salts was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/266/files/
Rekord szczegółowy - Podobne rekordy
6.
Numerical calculation of varistor model for sinusoidal signal / Kostyla, P [ENY-ARTICLE-2008-124]
ZnO varistors are semiconductor devices with highly nonlinear current-voltage characteristic and are widely used as devices for overvoltage protection. [...]
http://zet10.ipee.pwr.wroc.pl/record/162/files/
Rekord szczegółowy - Podobne rekordy
7.
Franklin rods - sharp or blunt ? / Chrzan, K L [ENY-ARTICLE-2013-348]
This paper gives the historical background of 250 year old question: should the Franklin rod tip be sharp or blunt ? The earlier works, the new field results from USA and own laboratory experiments are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/435/files/
Rekord szczegółowy - Podobne rekordy
8.
Lightning impulse performance of polluted medium voltage insulators / Chrzan, K L [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-277]
The concentrated dry bands on many silicone rubber insulators and also on porcelain insulators were observed by means of termovision camera. [...]
http://zet10.ipee.pwr.wroc.pl/record/345/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:405 w Google Books
recid:405 w Google Scholar
recid:405 w Google Web
recid:405 w INSPEC