Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 10 rekordów  Szukanie trwało 0.01 sekund. 
1.
Influence of pollution layer thickness on flashover voltage of HV insulators / Wankowicz, J ; Chrzan, K L ; Pohl, Z [ENY-ARTICLE-2012-325]
The pollution characteristics (the relationships of flashover voltage and SDD or maximum current Imax ) for insulators contaminated with uniform or nonuniform coatings with different thickness h are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/412/files/
Rekord szczegółowy - Podobne rekordy
2.
Influence of High Voltage Insulator on Pollution Flashover Voltage / Wankowicz, J G ; Pohl, Z [ENY-ARTICLE-2009-233]
Results of pollution flashover voltage measurements and optical observation obtained for high voltage insulators placed in the vertical and the horizontal positions are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/292/files/
Rekord szczegółowy - Podobne rekordy
3.
Impulse flashover of strings containing standard and semi-conducting disc insulators / Chrzan, K L ; Elsaesser, O [ENY-ARTICLE-2012-324]
Insulators with semi-conducting glazes (SCG insulators) are used mainly in heavily polluted areas. [...]
http://zet10.ipee.pwr.wroc.pl/record/411/files/
Rekord szczegółowy - Podobne rekordy
4.
Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators / Chrzan, K L ; Schwarz, H ; Haeusler, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-278]
The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. [...]
http://zet10.ipee.pwr.wroc.pl/record/346/files/
Rekord szczegółowy - Podobne rekordy
5.
Hygroscopic Properties of Pollutants on HV Insulators / Chrzan, K L ; Pohl, Z ; Kowalak, T [I07/1988/P-337] [ENY-ARTICLE-2008-212]
The mechanism of moisture absorption by an insulator surface contaminated with different salts was described. [...]
http://zet10.ipee.pwr.wroc.pl/record/266/files/
Rekord szczegółowy - Podobne rekordy
6.
PSPICE appliction for modelling of cap and pin insulator strings / Chrzan, K L ; Rebizant, W [ENY-ARTICLE-2012-318]
The use of PSPICE program in HV engineering is shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/405/files/
Rekord szczegółowy - Podobne rekordy
7.
Influence of profile on the pollution performance of ceramic long-rod insulators / Chrzan, K L [ENY-ARTICLE-2013-349]
The long rod insulators with different profiles were shown. [...]
http://zet10.ipee.pwr.wroc.pl/record/436/files/
Rekord szczegółowy - Podobne rekordy
8.
Leakage currents on naturally contaminated porcelain and silicone insulators. / Chrzan, K L [ENY-ARTICLE-2012-308]
The leakage current measurements on standard post insulators and on rod insulators without sheds were carried out. [...]
http://zet10.ipee.pwr.wroc.pl/record/395/files/
Rekord szczegółowy - Podobne rekordy
9.
Artificial rain test of outdoor long rod insulators / Chrzan, K L ; Streubel, H [ISBN 978-0-620-44584-9] [ENY-ARTICLE-2009-279]
Due to the decrease of industrial contamination emission nearly the whole territory of Poland belongs to the pollution class light. [...]
http://zet10.ipee.pwr.wroc.pl/record/347/files/
Rekord szczegółowy - Podobne rekordy
10.
Probes for spot measurement of surface conductivity on polluted insulators / Chrzan, K L ; Stec, C ; Farzaneh, M [doi:10.1049/iet-smt:20060044] [ENY-ARTICLE-2008-218]
The surface conductivity of insulators in the field is often non-uniformly distributed. [...]
http://zet10.ipee.pwr.wroc.pl/record/272/files/
Rekord szczegółowy - Podobne rekordy