Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 27 rekordów  1 - 10następnykoniec  skocz do rekordu: Szukanie trwało 0.01 sekund. 
1.
Internal partial discharges test for metal oxide surge arresters / Chrzan, K L [ENY-ARTICLE-2012-327]
Proposals for testing of surge arresters performance under internal partial discharge stress by Sakshaug, Chrzan and Korycki have been presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/414/files/
Rekord szczegółowy - Podobne rekordy
2.
Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Rekord szczegółowy - Podobne rekordy
3.
Changes in varistors properties after radial field test / Jaroszewski, M ; Korycki, P ; Wieczorek, K ; Zakrzewski, J [ENY-ARTICLE-2008-179]
ZnO varistors are used in commercial surge arresters in high voltage application in the area of power engineering. [...]
http://zet10.ipee.pwr.wroc.pl/record/229/files/
Rekord szczegółowy - Podobne rekordy
4.
Internal Arcing Test on Polluted High Voltage Surge Arresters / Chrzan, K L ; Kohler, W ; Feser, K [ENY-ARTICLE-2009-234]
A test to prove the performance of extremely non-uniform polluted single unit metal oxide (MO) and gapped arresters (SiCA) is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/293/files/
Rekord szczegółowy - Podobne rekordy
5.
Behaviour of Zinc Oxide Surge Arresters Under Pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [ENY-ARTICLE-2008-214]
This paper presents results of pollution tests with A. [...]
http://zet10.ipee.pwr.wroc.pl/record/268/files/
Rekord szczegółowy - Podobne rekordy
6.
Termovision diagnostics of metal oxide surge arresters / Chrzan, K L [I07/2007/I-043] [ENY-ARTICLE-2008-187]
The surge arresters diagnostics based on infrared temperature measurement was evaluated. [...]
http://zet10.ipee.pwr.wroc.pl/record/238/files/
Rekord szczegółowy - Podobne rekordy
7.
Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Rekord szczegółowy - Podobne rekordy
8.
Temperature monitoring of metal oxide surge arresters / Chrzan, K L ; Hinrichsen, V. [ENY-ARTICLE-2013-343]
Varistor overtemperature above the ambient is an important state parameter of metal oxide surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/430/files/
Rekord szczegółowy - Podobne rekordy
9.
Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Rekord szczegółowy - Podobne rekordy
10.
Degradation of metal oxide varistors caused by electrical stresses / Chrzan, K L [ENY-ARTICLE-2013-350]
The degradation of ZnO elements under AC or DC operating voltage and impulse current is described. [...]
http://zet10.ipee.pwr.wroc.pl/record/437/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:414 w Google Books
recid:414 w Google Scholar
recid:414 w Google Web
recid:414 w INSPEC