Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 10 rekordów  Szukanie trwało 0.01 sekund. 
1.
New concept for fault location in series-compensated parallel lines / Saha, M ; Wikstrom, K ; Izykowski, J ; Rosolowski, E [I08/2001/I-022] [ENY-ARTICLE-2008-060]
New concept for fault location in series- compensated parallel lines is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/69/files/
Rekord szczegółowy - Podobne rekordy
2.
Modern spectral analysis of non-stationary signals in electrical power systems / Leonowicz, Z ; Lobos, T ; Schegner, P [RZ I07/2002/I-048] [ENY-ARTICLE-2009-251]
A novel approach to harmonic and interharmonic analysis, based on the “subspace” methods, is proposed. [...]
http://zet10.ipee.pwr.wroc.pl/record/312/files/
Rekord szczegółowy - Podobne rekordy
3.
Accurate Location of Faults on Three-Terminal Line with Use of Three-End Unsynchronised Measurements / Izykowski, J ; Rosolowski, E ; Molag, R ; Balcerek, P ; et al [ENY-ARTICLE-2008-157]
This paper presents a new fault location algorithm for three-terminal line utilising unsynchronised measurements of three-end currents and voltages. [...]
http://zet10.ipee.pwr.wroc.pl/record/204/files/
Rekord szczegółowy - Podobne rekordy
4.
Application of lightning location systems for fault detection on transmission and distribution lines / Chrzan, K L ; Bodzak, P ; Gajda, W [ENY-ARTICLE-2012-326]
The lightning location systems were installed in many countries during last twenty years. [...]
http://zet10.ipee.pwr.wroc.pl/record/413/files/
Rekord szczegółowy - Podobne rekordy
5.
A New Fault Location Algorithm for Use with Current Differential Protective Relays of Two-Terminal Line / Izykowski, J ; Rosolowski, E ; Saha, M [ENY-ARTICLE-2008-156]
A new fault location algorithm utilising synchronised measurements of two-end currents and one-end voltage is presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/203/files/
Rekord szczegółowy - Podobne rekordy
6.
Modeling of overhead transmission lines with line surge arresters for lightning overvoltages / Jaroszewski, M ; Pospieszna, J ; Ranachowski, P ; Rejmund, F [ENY-ARTICLE-2012-312]
Lightning is one of the most significant source of overvoltages in overhead transmission lines. [...]
http://zet10.ipee.pwr.wroc.pl/record/399/files/
Rekord szczegółowy - Podobne rekordy
7.
Modeling of overhead transmission lines with line surge arresters for lightning overvoltages / Jaroszewski, M ; Pospieszna, J ; Ranachowski, P ; Rejmund, F [ENY-ARTICLE-2008-182]
Lightning is one of the most significant source of overvoltages in overhead transmission lines. [...]
http://zet10.ipee.pwr.wroc.pl/record/232/files/
Rekord szczegółowy - Podobne rekordy
8.
Transiente Vorgänge bei Erdschlüssen in Mittelspannungsnetzen / Lobos, T [I08/1975/I-097] [ENY-ARTICLE-2008-061]
Heim Erdschluss in Netzen mit isoliertem Sternpunkt und induktiver Sternpunkterdung treten transiente Vorgänge auf, die meistens einen schwingenden Charakter haben, da das Netz ein System mit passiven Elementen L und C bildet. [...]
http://zet10.ipee.pwr.wroc.pl/record/70/files/
Rekord szczegółowy - Podobne rekordy
9.
Analysis of Three Phase Signal using Wigner Spectrum / Leonowicz, Z ; Lobos, T [ENY-ARTICLE-2008-032]
New method of observation and diagnosis of inverter-fed induction motor drives is developed and tested. [...]
http://zet10.ipee.pwr.wroc.pl/record/39/files/
Rekord szczegółowy - Podobne rekordy
10.
Analysis of non-stationary signals in power systems / Leonowicz, Z [ENY-ARTICLE-2008-002]
Classical techniques to estimate the spectrum of the multi-component signal are based on Fourier-based transformations. [...]
http://zet10.ipee.pwr.wroc.pl/record/2/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:69 w Google Books
recid:69 w Google Scholar
recid:69 w Google Web
recid:69 w INSPEC