Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 14 rekordów  1 - 10następny  skocz do rekordu: Szukanie trwało 0.00 sekund. 
1.
The effect of a metallic particle near a spacer on flashover phenomena in SF6. / Mazurek, B ; Cross, J D ; Heeswijk van, R G [I07/1992/P-451] [ENY-ARTICLE-2008-072]
This paper presents a study of the flashover mechanism initiated by metallic particles in SF6 gas. [...]
http://zet10.ipee.pwr.wroc.pl/record/81/files/
Rekord szczegółowy - Podobne rekordy
2.
Effect of area on surface flashover voltage in vacuum / Cross, J D ; Mazurek, B [ISSN: 0018-9367INSPEC:3152462DOI: 10.1109/14.2330] [ENY-ARTICLE-2008-041]
It is known that the breakdown voltage in a vacuum insulation system drops with an increase in linear dimension of electrodes and with an increase in the number of insulating spacers bridging the gap. [...]
http://zet10.ipee.pwr.wroc.pl/record/49/files/
Rekord szczegółowy - Podobne rekordy
3.
The Effect of Low Temperature on the Role Played by Electrodes in Vacuum Breakdown / Mazurek, B [I07/1988/P-343] [ENY-ARTICLE-2008-070]
Electrical breakdown requires the creation of plasma in inter electrode space. [...]
http://zet10.ipee.pwr.wroc.pl/record/79/files/
Rekord szczegółowy - Podobne rekordy
4.
The Effect of the Number of Spacer Insulators on the Breakdown Voltage of Vacuum Insulation / Juchniewicz, J ; Mazurek, B ; Tyman, A [ENY-ARTICLE-2008-226]
It was shown that when extended high voltage vacuum insulation is being considered, the effect of the he number of spacer insulators on the breakdown voltage of the system has to be taken into account. [...]
http://zet10.ipee.pwr.wroc.pl/record/281/files/
Rekord szczegółowy - Podobne rekordy
5.
AC Flashover Voltage in Vacuum for Different Electrode Diameters and Different Pressures / Tyman, A [ENY-ARTICLE-2008-223]
Application of vacuum insulation in cryo-installations, for example cryocables, requires investigations made on specimens and laboratory arrangements which would be very close to those met in practice. [...]
http://zet10.ipee.pwr.wroc.pl/record/278/files/
Rekord szczegółowy - Podobne rekordy
6.
Fast cathode processes in conditioning of vacuum electrodes / Cross, J D ; Mazurek, B [ENY-ARTICLE-2008-069]
High - speed streak photographs of vacuum breakdown show oscillations in light emission at the cathode . [...]
http://zet10.ipee.pwr.wroc.pl/record/78/files/
Rekord szczegółowy - Podobne rekordy
7.
Atmospheric Pressure Cold Plasma Reactor with Back Discharges and Parallel Gas Flow / Kacprzyk, R ; Miśta, W ; Czapka, T [ENY-ARTICLE-2011-302]
none.
http://zet10.ipee.pwr.wroc.pl/record/387/files/
Rekord szczegółowy - Podobne rekordy
8.
Inactivation of Yersinia enterocolitica Gram-negative bacteria using high voltage technique / Lubicki, P ; Cross, J D ; Jayaram, S ; Mazurek, B ; et al [I07/1995/I-220] [ENY-ARTICLE-2008-077]
High voltage pulses of peak voltages U=5-75 kV and rise times tp=500-1300 ns were applied with repetition frequency f=lHz in order to cause the irreversible electroporation of Gram negative bacteria Yersinia enterocolitica. [...]
http://zet10.ipee.pwr.wroc.pl/record/95/files/
Rekord szczegółowy - Podobne rekordy
9.
Studies of Epoxy Spacers Subjected to Internal and External Partial Discharge and SF6 Byproducts / Braun, J M ; Chu, F Y ; Tyman, A [ENY-ARTICLE-2008-230]
Ihe reliability of gas insulated switchgear (GIS) has generally been good. [...]
http://zet10.ipee.pwr.wroc.pl/record/285/files/
Rekord szczegółowy - Podobne rekordy
10.
Franklin rods - sharp or blunt ? / Chrzan, K L [ENY-ARTICLE-2013-348]
This paper gives the historical background of 250 year old question: should the Franklin rod tip be sharp or blunt ? The earlier works, the new field results from USA and own laboratory experiments are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/435/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:81 w Google Books
recid:81 w Google Scholar
recid:81 w Google Web
recid:81 w INSPEC