Repozytorium Eny Politechnika Wrocławska

Repozytorium W. Elektrycznego Politechniki Wrocławskiej Znaleziono 22 rekordów  początekpoprzedni13 - 22  skocz do rekordu: Szukanie trwało 0.01 sekund. 
13.
Hydrogen Influence on Properties of Thin Film Arresters / Jaroszewski, M [ENY-ARTICLE-2008-129]
The influence of H2 atmosphere on the temperature dependence of resistivity of Zn-Bi-O thin films were characterized in this study. [...]
http://zet10.ipee.pwr.wroc.pl/record/167/files/
Rekord szczegółowy - Podobne rekordy
14.
Numerical calculation of varistor model for sinusoidal signal / Kostyla, P [ENY-ARTICLE-2008-124]
ZnO varistors are semiconductor devices with highly nonlinear current-voltage characteristic and are widely used as devices for overvoltage protection. [...]
http://zet10.ipee.pwr.wroc.pl/record/162/files/
Rekord szczegółowy - Podobne rekordy
15.
Pollution Performance of 110 kV Metal Oxide Arresters / Chrzan, K L ; Pohl, Z ; Grzybowski, S ; Kohler, W [ENY-ARTICLE-2008-216]
Pollution test results of single unit 110 kV metal oxide surge arresters with porcelain housing according to the solid layer and salt fog methods are presented. [...]
http://zet10.ipee.pwr.wroc.pl/record/270/files/
Rekord szczegółowy - Podobne rekordy
16.
Influence of Partial Discharges on ZnO Varistors / Jaroszewski, M [ENY-ARTICLE-2008-181]
The varistors used in HV overvoltage limiters are constantly exposed to operating voltage and environmental hazards and also to transient hazards associated with, among others, overvoltages or pollution. [...]
http://zet10.ipee.pwr.wroc.pl/record/231/files/
Rekord szczegółowy - Podobne rekordy
17.
An assessment of ageing of oxide varistors exposed to pulse hazards using dielectric spectroscopy / Jaroszewski, M ; Pospieszna, J [I07/2004/I-019] [ENY-ARTICLE-2008-115]
The common use of zinc oxide varistors has brought about qualitative changes in the overvoltage protection of electronic and electric power equipment. [...]
http://zet10.ipee.pwr.wroc.pl/record/144/files/
Rekord szczegółowy - Podobne rekordy
18.
Electrochemical gas sensors can make DGA a portable screening procedure / Zylka, P [RZ I07/04/I-001] [ENY-ARTICLE-2008-047]
Dissolved Gas Analysis (DGA) in its classical chromatography-based laboratory approach has become a routine procedure for testing and assessment of power transformer condition. [...]
http://zet10.ipee.pwr.wroc.pl/record/56/files/
Rekord szczegółowy - Podobne rekordy
19.
Influence of moisture and partial discharges on the degradation of high-voltage surge arresters. / Chrzan, K L [ENY-ARTICLE-2012-321]
This paper reports the influence of moisture and internal partial discharges on the degradation of metal oxide varistors in high-voltage surge arresters. [...]
http://zet10.ipee.pwr.wroc.pl/record/408/files/
Rekord szczegółowy - Podobne rekordy
20.
Behaviour of zinc oxide surge arresters under pollution / Feser, K ; Kohler, W ; Qiu, D ; Chrzan, K L [I07/1990/I-114] [ENY-ARTICLE-2008-213]
This paper presents results of pollution tests with AC voltages which were carried out with a multi-unit zinc oxide arrester. [...]
http://zet10.ipee.pwr.wroc.pl/record/267/files/
Rekord szczegółowy - Podobne rekordy
21.
Termovision diagnostics of metal oxide surge arresters / Chrzan, K L [I07/2007/I-043] [ENY-ARTICLE-2008-187]
The surge arresters diagnostics based on infrared temperature measurement was evaluated. [...]
http://zet10.ipee.pwr.wroc.pl/record/238/files/
Rekord szczegółowy - Podobne rekordy
22.
Thin Film Arresters Obtained by Metal Evaporation / Ziaja, J [ENY-ARTICLE-2008-136]
Ceramic varistors based on zinc oxide have been shown to have excellent properties as protection devices used in power industry. [...]
http://zet10.ipee.pwr.wroc.pl/record/174/files/
Rekord szczegółowy - Podobne rekordy

Jeżeli nie znaleziono tego czego szukasz, spróbuj szukać na innych serwerach:
recid:230 w Google Books
recid:230 w Google Scholar
recid:230 w Google Web
recid:230 w INSPEC